Battery selector Dual Bank from BEP where start and consumption are separated. 400 A constant, 600 A up to 5 min and 1500 A/10 seconds. Max = 48V DC.
Ez-Mount means that the switch itself can be mounted before cables are connected.
Pos. 1 = Battery 1 is connected only for consumption and start is not connected.
Pos. 1-2 = battery 1 is connected only to consumption and battery 2 is connected only to Start.
Pos. Parallel = Emergency connection to connect the batteries together.
Pos. Off = both batteries are disconnected.
LxWxD: 100 mm
Recess: 35 mm
Connection: 10 mm bolt
!